- 92 -
Setup
range
0.0:
0.1s~5.0s
0.0:inenabled
0.1s~5.0s
Set up detection CAN break time, if the driver did not receive data within the
setup time, then it will alarm 42.
Group A3 Servo oil pump control group
oil pressure
control mode
Factory default
value
0
0
Non-oil pressure control mode
1
Driver oil pressure control mode 1
2
Driver oil pressure control mode 2
3
CAN oil pressure mode(For special use)
A3-00
Setup
range
4 Reserved
A3-00=“0”:Non-oil pressure control mode
A3-00=“1”:Driver oil pressure control mode 1.
CAN setup flow, oil pressure command and A13 analog channel
provides oil pressure feedback command,driver conduct oil pressure control.
A3-00=“2”: Driver oil pressure control mode 2.
A13 analog channel provides oil pressure command, A12 analog
channel provides flow command, and A13 analog channel provides oil
pressure feedback command, driver conducts oil pressure control.
A3-00=“3”:CAN oil pressure contol mode (For special use), group A3 control group
parameters of the servo oil pump disabled.
A3-00=“4”:保留。Reserved.
Maximum rotation
speed
Factory default
value
2000rpm
A3-01
setup range
The maximum frequency of frequency lower limit
corresponding to rotation speed~30000rpm
The corresponding system output flow sets motor running maximum speed, the
recommendations of the setup value is less than 1.4% of the motor rated speed (F1-05).