- 162 -
Function
Code
Function Code
Description
Setup
F0-03 = “9”(Communication setup is
frequency source)
F0-07
Frequency source
selection
0 (Non-auxiliary frequency source)
F0-17 Speed-up time 0.0s
F0-18 Speed-down time 0.0s
F1-00
Motor type
selection
2 (Synchronous motor)
F4-00
DI1 terminal
function selection
11(Running enabled)
F4-01
DI2 terminal
function selection
48 (Oil pressure control PID select
terminal 1)
F4-02
DI3 input function
selection
49(Oil pressure control PID select
terminal 2)
F4-03
DI4 input function
selection
9 (Fault reset)
F4-04
DI5 input function
selection
50(CAN communication enabled)
F5-01
DO1 output
function selection
2 (Fault output)
F5-02
DO2 output
function selection
23(Swashplate switch)
F5-03 DO3 output
function selection
24 (Pressure control status output)
Modify the above-mentioned parameters in the oil pressure control mode, it
may be power-failure recorded (which the driver to repower is to restore setup
value automatically), When the oil pressure mode switches to non-oil pressure
mode, the above parameters will be restored to switch to the numerical value
which is before oil pressure control mode.
3) AI zero drift auto-correction(A3-20):
Set AI zero drift auto correction parameter A3-20 to 1, the driver will conduct an
AI zero drift auto correct operation:
Write the detection value zero drift of three analog channel into the parameters,
they are F4-18 (AI1 is the minimum input), F4-23 (AI2 is the minimum input),
F4-28 (AI3 is the minimum input). The detection value of zero drift can be