- 197 -
Function
code
Name
LED
display
Setup range
Minimu
m unit
Factor
y
default
value
Modifi
c-ation
descri
p-tion
A2-00
Baud rate
selection
Baud rate
selection
020k
150k
2125k
3250k
4500k
51M
1 5
A2-01
CAN
communicat
ion address
CAN
communicati
on address
1255
1 1
A2-02
CAN
communicat
ion
continuous
time
CAN
communicati
on
continuous
time
0.0sinenabled
0.1s5.0s
0.1s 0.3s
Group F0 Basic Function Group
F0-02
Command
source
selection
Command
source
selection
0: Operation panel
running command
channel (LED
OFF)
1: terminal
command channel
(LED ON)
2: serial port
command channel
(LED flashes)
1 0
Group F1 Motor Parameters
F1-00
Motor type
selection
Motor type
selection
Permanent
magnetic
synchronous
motor
1 2
F1-01
Rated
power
Rated
power
0.4kW
1000.0kW
0.1kW
Model
depend