Loading...
- 28 -
When the servo driver power is not higher than IS300T040, the A size can be
omitted. When the servo driver power is higher than IS300T040, the A size
shall be higher than 50mm.
When installing the upper and lower parts of the servo driver, the insulating
splitter is required.
Fig.3-1 Servo Driver Installation Diagram
3.1.2 Cooling problem shall be taken into account during the mechanical
installation. Pay attention to the following items:
1) Install the servo driver vertically so that the heat may be expelled
from the top. However, the equipment cannot be installed upside
down. If there are multiple servo drivers, parallel installation is a
better choice. In applications where the upper and lower parts of the
driver need to be installed, please refer to “Servo driver Installation
Diagram” and install an insulating splitter.
2) The mounting space shall be as indicated as the above figure, so as
to ensure the cooling space of the Servo driver. However, the heat
dissipation of other devices in the cabinet shall also be taken into
account.
3) The installation bracket must be flame retardant.
4) In the applications where there are metal dusts, it is recommended to
mount the radiator outside the cabinet. In this case, the space in the
sealed cabinet shall be large enough.
3.1.3 Removing and mounting the down cover plate:
The IS300T030 (included) employs plastic enclosure. Please refer to Figure
3-2 for removing the lower cover plate of the plastic enclosure. The hooker of
Physical Dimensions
Power level
B A
IS300T030 100mm No requirements
IS300T035—IS300T050 200mm 50mm
IS300T070 300mm 50mm

Table of Contents