- 30 -
Fig.3-3 Removing the Down Cover Plateof Sheet-Metal Enclosure
3.1.4 The Installation of permanent-magnet synchronous servo motor and
pressure transducer
Servo motors work process will appear to start and stop state from repeated
high-speed.It easily lead to motor vibration, causing system instability.Please
make sure that the electrical installation is fixed and reasonable.
Take the following one installation fixed way (the massive rubber cushion with
fixed bolts) as an example for reference.
screw bolt
rubber mat
Injection molding machine
supporting frames
screw nut
Fig.3-4 Permanent-magnet Synchronous Servo Motor Installation Diagram