Fig.3-7 Layout of Control Circuit Terminals
2)Function description of control terminal:
Table 3-3 Description of Control Terminal Function of Servo Driver
Type Terminal Terminal name Function description
+10V-GND 10V power supply
Provide 10V±10% power supply for
external- units, and the maximum
output current is 10mA.
It is generally used as the operating
power supply for the external
potentiometer.
The potentiometer resistance range
is 1kΩ~ 5kΩ.
power supply
+13V-GND
Pressure sensor
power supply
Provide 13V±10% power supply for
external units.
The maximum output current is
10mA.
It is generally used as the operating
power supply for pressure sensor.