- 59 -
Function
code
Name LED display Setup range
Minimu
m unit
Factory
default
value
Modific-
ation
descrip-t
ion
F0-01 Control mode Control mode
0: Speed sensorless
vector control (SVC)
1: Speed sensor
vector control (VC)
2:V/F control
1 1
F0-02
Command source
selection
Command
source selection
0: 0:Operation panel
running command
channel (LED OFF)
1: Terminal
command channel
(LED ON)
2: Serial port
command channel
(LED flashes)
1 0
F0-03
Main frequency
source X
selection
Frequency
source X
selection
0: Digital setup UP
and DOWN
adjustment
(non-recorded)
1: Digital setup UP
and DOWN
adjustment
(recorded)
2: Al1
3: Al2
4: Al3
5:Reserved
6: MS speed
7: Resvered
8: Resvered
9: Communication
setup
1 1