- 67 -
Function
code
Name LED display Setup range
Minimu
m unit
Factory
default
value
Modific-
ation
descrip-t
ion
F3-01 Torque boost Torque boost
0.0Automatic
0.1%30.0%0.
0:(automatic)0.1% to
30.0%
0.1% 1.0%
F3-02
Cutoff frequency
of torque boost
Cutoff frequency
of torque boost
0.00 ~ maximum
frequency
0.01Hz 50.00Hz
F3-03
V/F Frequency
point 1
V/F Frequency
point 1
0.00Hz ~ rated motor
frequency
0.01Hz 0.00Hz
F3-04
V/F voltage point
1
V/F voltage point
1
0.0%100.0% 0.1% 0.0%
F3-05
V/F frequency
point 2
V/F frequency
point 2
0.00Hzmotor rated
frequency
0.01Hz 0.00Hz
F3-06
V/F voltage point
2
V/F voltage point
2
0.0%100.0% 0.1% 0.0%
F3-07
V/F frequency
point 3
V/F frequency
point 3
0.00Hzmotor rated
frequency
0.01Hz 0.00Hz
F3-08
V/F voltage point
3
V/F voltage point
3
0.0%100.0% 0.1% 0.0%
F3-09
Slip
compensation
coefficient
Slip
compensation
coefficient
0.0%200.0% 0.1% 0.0%
F3-10 AVR selection AVR selection
0: Inenabled
1: Enabled
2: Inenabled only at
the time of
deceleration
1 2
F3-11
Oscillation
suppression gain
Oscillation
suppression gain
0100
1
Mmodel
depende
nt