- 77 -
Function
code
Name LED display Setup range
Minimu
m unit
Factory
default
value
Modific-
ation
descrip-t
ion
F6-11
DC brake
beginning
frequency at stop
Brake frequency
at stop
0.00Hz ~ maximum
frequency
0.01Hz 0.00Hz
F6-12
DC brake waiting
time at stop
Brake waiting at
stop
0.0s36.0s 0.1s 0.0s
F6-13
DC brake current
at stop
DC brake current
at stop
0%100% 1% 0%
F6-14
DC brake time at
stop
DC brake time at
stop
0.0s36.0s 0.1s 0.0s
F6-15 Brake use ratio Brake use ratio 0%100% 1% 100%
Group F7 Keyboard and Display
F7-00
LCD Language
selection
Language
selection
0: Chinese
1: English
1 0
F7-01
MF.K Key
function selection
MF.K Key
function
selection
0:MF.K inenabled
1: Switching
between operation
panel command
channel and remote
command channel
(terminal command
channel or serial port
communication
command channel)
2: Switching
between forward
rotation and reverse
rotation
3: Forward rotation
Jog
1 0