5 Parameter Table
- 25 -
Para� No� Para� Name Setting Range Unit Default Property
A3-26 Pressure command s-curve
deceleration lter time 1
0�001s to 1�000s 0�001s 0�030s
A3-27 Overshoot suppression detection
factor 1
0 to 2000 1 200
A3-28 Overshoot suppression factor 1 0 to 3�000 0�001 0�200
A3-29 Pressure loop gain factor 0�20 to 5�00 0�01 1�00
A3-30 Max� torque during switch from
pressure control to ow control state
50�0% to 250�0% 0�1% 160�0%
A3-31 Pressure command delay time 1 0�000s to 0�500s 0�001s 0�000s
A3-32 Slave drive min� Input 0�0% to A3-34 0�1% 0�0%
A3-33 Slave drive min� Input frequency� -100�0% to 100�0% 0�1% 0�0%
A3-34 Slave drive mid-point input A3-32 to A3-36 0�1% 0�0%
A3-35 Slave drive mid-point input
frequency
-100�0% to 100�0% 0�1% 0�0%
A3-36 Slave drive max� Input A3-34 to 100�0% 0�1% 100�0%
A3-37 Slave drive max� Input frequency� -100�0% to 100�0% 0�1% 100�0%
A3-38 Multi-pump host check whether to
enable slave pump
0: slave enable forbidden
1: slave enable permitted
1 0
A3-39 Multi-pump conuence mode
pressure holding gain
20 to 800 1 100
A3-40 Multi-pump injection state acceptable
pressure error during gain decrease
0�0 to 50�0 kg 0�1kg 5�0kg
A3-41 Multi-pump injection state acceptable
min� Flow during gain decrease
0 to 30000 rpm 1 rpm 0 rpm
A3-42 Multi-pump injection state ow
detection time during gain decrease
0�200 to 2�000s 0�001s 0�400s
A3-43 Multi-pump CANLink state pressure
error threshold to Disable slave
pump
0 to 50�0 kg 0�1 kg 5�0 kg
A3-44 Multi-pump CANLink state min. ow
to Disable slave pump
-100�0% to 100�0% 0�1% 0�0%
A3-45 Withdrew speed command slave
pump delays to stop
0�100 to 5�000s 0�001s 1�000s
A3-46 Withdrew speed command slave
pump deceleration time
0�001 to 5�000s 0�001s 0�200s
A3-47 Valve decompression enable delay 0�001 to 5�000s 0�001s 0�100s
A3-48 Valve decompression Disable delay 0�001 to 5�000s 0�001s 0�100s
A3-49 Pressure error lower threshold for
valve decompression enable
0�0 to A3-02 (system pressure) 0�1 kg 0�0 kg
A3-50 Pressure command lower threshold
for valve decompression enable
0�0 to A3-02 (system pressure) 0�1 kg 0�0 kg
A3-51 Current lower threshold for pressure
sensor fault detection
20 to 300% 1% 100%
A3-52 Speed upper threshold for pressure
sensor fault detection
20 to 100% 1% 50�0%
A3-53 Deceleration time of second set high
ow
0�000 to 5�000s 0�001s 0�100s
A3-54 Threshold of second set high ow 0 to 100�0% 0�1% 100�0%