Parameter Description MD280/MD280N User Manual
- 156 -
Reverse rotation
control
Factory default
value
0
0 Reverse rotation enabled
F5-09
Setup
value
1 Reverse rotation disabled
0: Reverse rotation enabled: It can control the reverse rotation of the
inverter through the keyboard, terminals or communications.
1: Reverse rotation disabled: The reverse rotation control function is invalid
when the inverter is under control of keyboard, terminals or
communications.
Remark: Reverse rotation control disabled is valid for the jog running of the
inverter.
Run with frequency
below frequency lower
limit
Factory default
value
0
0 Run with frequency lower limit
F5-10
Setup
range
1 Delay to stop
It is used to select the running status of the inverter when the setup
frequency is lower than the frequency lower limit.
0: Running with frequency lower limit: If the setup frequency is lower than
the frequency lower limit, the inverter will run with the frequency lower limit.
1: Stop: If the setup frequency is lower than the frequency lower limit during
the inverter running process, the inverter will stop. If the setup frequency is
lower than the frequency lower limit at the time of startup, the inverter will
not start.
In order to prevent the motor from running at low speed for long period of
time, it can use this function to stop the unit.
Delay duration of stop with
frequency below frequency
lower limit
Factory
default value
0.0s
F5-11
Setup range 0.0s to 3600.0s
It refers to the delay duration from the time when the delay stop is set for
the setup frequency lower than the frequency lower limit (F5-10) to the time
when the frequency is lower than the frequency lower limit.