3 Easy Setup
- 9 -
3 Easy Setup
3�1 Logic of Control
Complete Timing Diagram
F0-08
[x.x Hz]
F0-18
F0-17 F6-09
F6-08 [x.x Sec]
[x.x Sec] [x.x% ] [x.x% ]
F6-11
DC injection braking 2 frequency threshold
F6-04
[x.x Sec]
F6-03
F6-08 F6-09
[x.x Hz] [x.x% ] [x.x% ]
0
F6-06 [ x.x Sec]:
F6-13 [ x % ] : F6-14 [ x.x Sec]:
DC injection braking 1 active time(if F6-00=0) DC injjection braking 2 level
DC injection braking 2 active time
Pre-excitation active time (if F6-00=2)
F6-05 [ x % ] :
F6-12 [ x.x Sec] (default: 0.0 Sec)
DC injection braking 1 level (if F6-00=0) DC injection braking 2 delay time
Pre-excitation level (if F6-00=2)
t1
Time
DI 1
Forward
IGBT's Ac tive
Frequency
Frequency
output
command
[ x.x Hz]: default 0.0 Hz
t9
ON
OFF
ON
OFF
t2
t4
t5
t6
t7
t8
t3
0%
DC Injec tion/
Pr e-exc itation
Motor Current
20%
40%
Stages
100%
100%
50%
0%