EasyManua.ls Logo

Inovance MD310 Series - Group F7: Keypad Control and LED Display

Inovance MD310 Series
54 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5 Parameter Table
- 34 -
Group F7: Keypad Control And LED Display
Para� No� Para� Name Setting Range Unit Default Commission
F7-01 MF�K Key function selection 0 to 5 N�A� 5
F7-02 STOP/RESET key function 0 to 1 N�A� 1
F7-03 LED display running
parameters 1
0000 to FFFF N�A� 1F
F7-04 LED display running
parameters 2
0000 to FFFF N�A� 0
F7-05 LED display stop
parameters
0000 to FFFF N�A� 33
F7-06 Load speed display
coefcient
0�0001 to 6�5000 N�A� 1�0000
F7-07 Heatsink temperature of
inverter module
0 to 100 °C -
F7-08 Product number N�A� N�A� N�A�
F7-09 Accumulative running time 0 to 65535 h N�A�
F7-10 Performance software
version
N�A� N�A� N�A�
F7-11 Functional software version N�A� N�A� N�A�
F7-12 Number of decimal places
for load speed display
Number of decimal places
for U0-19/U0-29
1: 1 decimal place
2: 2 decimal places
Number of decimal places
for U0-14
0: 0 decimal place
1: 1 decimal place
2: 2 decimal places
3: 3 decimal places
N�A� 21
F7-13 Accumulative power-on
time
0 to 65535 h N�A�
F7-14 Accumulative power
consumption
0 to 65535 kWh N�A�
F7-15 Temporary performance
software version
N�A� N�A� N�A�
F7-16 Temporary functional
software version
N�A� N�A� N�A�

Table of Contents

Related product manuals