Page #17 background imageLoading...
Page #17 background image
3 Easy Setup
- 16 -
Para� No� Para� Name Setting Range Unit Default Commission
F0-07 Frequency source
superposition selection
0: Main + Auxiliary
1: Main Auxiliary
2
: Maximum of main and auxiliary
3: Minimum of main and auxiliary
Frequency reference setting channel selection
0: Main frequency reference setting channel
1: Main + auxiliary operation
2: Switchover between main and auxiliary
3: Switchover between main and main +
auxiliary calculation
4: Switchover between auxiliary and main +
auxiliary calculation
Main and auxiliary calculation relationship
N�A� 00
F0-08 Preset frequency 0�00 to max frequency Hz 50�00
Serial comms�
PID reference
Simple PLC
Multi-reference
Pulse reference
Analog input
Fx
-xx
Digital input
(retentive)
F0-08
Digital input (non-retentive)
F0-08
Fx-xx
Fx-xx
Fx-xx
Fx-xx
Fx-xx
F0-04
Auxiliary frequency
reference
Main frequency
reference
Auxiliary
F
0-03
Auxiliary
Main
Sum of main and auxiliary
Main +
Auxiliary
Difference of main and auxiliary
Larger of main and auxiliary
Main - Auxiliary
Calculation
Main &
Auxiliary
F0-07
Ten's digit
F0
-
05
F0
-
06
Limit the auxiliary
for calculation
Calculation
result
F0-07
Unit's digit
F4-00 to F4-09 = 18
Final frequency
reference
Main
Larger of main and auxiliary
Min� (Main, Auxiliary)
Max� (Main, Auxiliary)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Inovance MD310 Series and is the answer not in the manual?

Inovance MD310 Series Specifications

General IconGeneral
BrandInovance
ModelMD310 Series
CategoryController
LanguageEnglish