EasyManua.ls Logo

Inovance MD310 T5.5B - Symptoms and Diagnostic Guidance

Inovance MD310 T5.5B
54 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4 Troubleshooting
- 25 -
Display Fault Name Possible Causes Solutions
Err28 User-dened fault 2 1. The user-dened fault 2 signal is input via DI
2. The user-dened fault 2 signal is input via
VDI�
Reset the fault�
Err29 Accumulative power-
on time reached
The accumulative power-on time reaches the
setting of F8-16�
Clear the record by performing parameter
initialization (set FP-01 to 2)�
Err30 Off load fault Ofoad when it’s running. Check the connection between motor and load�
Err31 PID feedback lost
during running
The PID feedback is lower than FA-26� Check the PID feedback signal or set FA-26 to a
proper value�
Err33 Communication
receiving timeout
inside drive board
1� Wirings become loose inside the AC drive
2� The drive board is abnormal�
3� The control board is abnormal�
1� Connect all wirings securely
2 and 3� Seek for maintenance�
Err40 Quick current limit 1� The load is too heavy or the rotor is locked�
2� The drive is of too small power class�
1: Reduce the load, or check the motor, or check
the machine whether it is locking the rotor
2: Select a drive of higher power class�
Err41 Motor switchover fault
during running
The current motor is switched over via a
terminal during running of the AC drive�
Switch over the motor only after the AC drive
stops�
Err42 Overspeed error 1� Locked-rotor occurs on the motor�
2� F9-69 and F9-70 are set improperly
3� Wirings between the AC drive and motor are
abnormal�
1� Check whether the machine is abnormal,
whether motor auto-tuning is not performed, and
whether the setting of F2-10 is small�
2� Set F9-69 and F9-70 properly
3� Check whether wirings between the AC drive
and motor break� If yes, reconnect the wirings
securely
Err96 Communication
receiving timeout
inside control board
1� Wirings become loose inside the AC drive
2� The drive board is abnormal�
3� The control board is abnormal�
1� Connect all wirings securely
2 and 3� Seek for maintenance�

Table of Contents