5 Parameter Table
- 35 -
Group F8: Auxiliary Functions
Para� No� Para� Name Setting Range Unit Default Commission
F8-00 JOG running frequency 0�00 to max frequency Hz 2�00
F8-01 JOG acceleration time 0�0 to 6500�0 s 20�0
F8-02 JOG deceleration time 0�0 to 6500�0 s 20�0
F8-03 Acceleration time 2 0�0 to 6500�0 s Model
dependent
F8-04 Deceleration time 2 0�0 to 6500�0 s Model
dependent
F8-05 Acceleration time 3 0�0 to 6500�0 s Model
dependent
F8-06 Deceleration time 3 0�0 to 6500�0 s Model
dependent
F8-07 Acceleration time 4 0�0 to 500�0 s Model
dependent
F8-08 Deceleration time 4 0�0 to 6500�0 s Model
dependent
F8-09 Frequency jump 1 0�00 to max frequency Hz 0�00
F8-10 Frequency jump 2 0�00 to max frequency Hz 0�00
F8-11 Frequency jump amplitude 0�00 to max frequency Hz 0�00
F8-12 Forward/Reverse rotation
dead-zone time
0�0 to 3000�0 s 0�0
F8-13 Reverse control 0: Enabled
1: Disabled
N�A� 0
F8-14 Running mode when set
frequency lower than
frequency lower limit
0: Run at frequency lower limit
1: Stop
2: Run at zero speed
N�A� 0
F8-15 Droop control 0�00 to 10�00 Hz 0�00
F8-16 Accumulative power-on time
threshold
0 to 65000 h 0
F8-17 Accumulative running time
threshold
0 to 65000 h 0
F8-18 Startup protection 0: No
1: Yes
N�A� 0
F8-19 Frequency detection value
(FDT1)
0�00 to max frequency Hz 50�00
F8-20 Frequency detection
hysteresis (FDT1 hysteresis)
0�0 to 100�0 (FDT1 level) % 5�0
F8-21 Detection range of frequency
reached
0�00 to 100 (max frequency) % 0�0
F8-22 Jump frequency during
acceleration/deceleration
0: Disabled
1: Enabled
N�A� 1
F8-25 Frequency switchover point
between acceleration time 1
and acceleration time 2
0�00 to max frequency Hz 0�00
F8-26 Frequency switchover point
between deceleration time 1
and deceleration time 2
0�00 to max frequency Hz 0�00
F8-27 Terminal JOG priority 0: Disabled
1: Enabled
N�A� 0

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Inovance MD310 T5.5B and is the answer not in the manual?

Inovance MD310 T5.5B Specifications

General IconGeneral
Rated Power5.5 kW
Output Current11 A
Frequency Range0 - 400 Hz
Cooling MethodForced air cooling
Storage Temperature-20°C to +60°C
Control ModeV/F control, Sensorless vector control
Protection FeaturesOvercurrent, overvoltage, undervoltage, overheat, overload, short circuit
Communication InterfaceRS485, Modbus
Ambient Temperature-10°C to +40°C
Humidity5% to 95% (non-condensing)
AltitudeUp to 1000 m
Input Voltage3-phase 380V AC