5 Parameter Table
- 40 -
Group FB: Wobble Frequency, Fixed Length And Count
Para� No� Para� Name Setting Range Unit Default Commission
FB-00 Wobble setting mode 0: Relative to the central frequency
1: Relative to the max frequency
N�A� 0
FB-01 Wobble frequency amplitude 0�0 to 100�0 % 0�0
FB-02 Wobble step 0�0 to 50�0 % 0�0
FB-03 Wobble cycle 0�1 to 3000�0 s 10�0
FB-04 Triangular wave rising time
coefcient
0�0 to 100�0 % 50�0
FB-05 Set length 0 to 65535 m 1000
FB-06 Actual length 0 to 65535 m -
FB-07 Number of pulses per meter 0�1 to 6553�5 N�A� 100�0
FB-08 Set count value 1 to 65535 N�A� 1000
FB-09 Designated count value 1 to 65535 N�A� 1000
Group FC: Multi-Reference And Simple PLC Function
Para� No� Para� Name Setting Range Unit Default Commission
FC-00 Reference 0 -100�0 to 100�0 % 0�0
FC-01 Reference 1 -100�0 to 100�0 % 0�0
FC-02 Reference 2 -100�0 to 100�0 % 0�0
FC-03 Reference 3 -100�0 to 100�0 % 0�0
FC-04 Reference 4 -100�0 to 100�0 % 0�0
FC-05 Reference 5 -100�0 to 100�0 % 0�0
FC-06 Reference 6 -100�0 to 100�0 % 0�0
FC-07 Reference 7 -100�0 to 100�0 % 0�0
FC-08 Reference 8 -100�0 to 100�0 % 0�0
FC-09 Reference 9 -100�0 to 100�0 % 0�0
FC-10 Reference 10 -100�0 to 100�0 % 0�0
FC-11 Reference 11 -100�0 to 100�0 % 0�0
FC-12 Reference 12 -100�0 to 100�0 % 0�0
FC-13 Reference 13 -100�0 to 100�0 % 0�0
FC-14 Reference 14 -100�0 to 100�0 % 0�0
FC-15 Reference 15 -100�0 to 100�0 % 0�0
FC-16 Simple PLC running mode 0 to 2 N�A� 0
FC-17 Simple PLC retentive
selection
00 to 11
N�A� 00
FC-18 Running time of simple PLC
reference 0
0�0 to 6500�0
s or h 0�0
FC-19 Acceleration/deceleration time
of simple PLC reference 0
0 to 3
N�A� 0
FC-20 Running time of simple PLC
reference 1
0�0 to 6500�0
s or h 0�0
FC-21 Acceleration/deceleration time
of simple PLC reference 1
0 to 3
N�A� 0
FC-22 Running time of simple PLC
reference 2
0�0 to 6500�0
s or h 0�0
FC-23 Acceleration/deceleration time
of simple PLC reference 2
0 to 3
N�A� 0
FC-24 Running time of simple PLC
reference 3
0�0 to 6500�0
s or h 0�0

Table of Contents