Installation
54
5.5.5 Storage
Store the AC drive in a clean and dry space, with an ambient temperature ranging
from 20℃ to +60℃ and a temperature change rate less than 1℃/min.
For long time storage, cover the AC drive or take other appropriate measures to
keep it from contamination and environmental influences.
For storage, pack the AC drive with the original packing box provided by Inovance.
Avoid exposing the AC drive to moisture, high temperature, or outdoor direct
sunlight for an extended period.
To avoid degradation of electrolytic capacitor during long‑term storage, energize
the AC drive once every six months, each time lasting at least 5 hours. Use a
regulator to increase the input voltage gradually to the rated value. For any doubt,
contact Inovance.
5.6 Cable Preparation
Table 5–9 Cables
Cable
Type
Cable
Name
Diagram Cable Type Cable Name Diagram
Main
circuit
cable
Power
cable
Control
circuit
cable
Signal cable
Ground
cable
Network
cable
5.7 Mechanical Installation
5.7.1 Installation Methods
The MD520 series AC drives support different installation methods depending on the
model.