3.1 Viewing and operation instruction of Function Code using operating Keypad:-
NICE 1000 adopt three level menu to conduct the parameter setting.
Three level menu include:
Function Parameter Group (First Level)
Function Code (Second Level)
Function Code Setting (Third Level)
Operation procedures are as follows
Example: Change function code F0-06 from 50.00Hz to 15.00Hz
Display
in Stop
In the three level menu, if the parameter has no flash bit, it means the function code can’t be changed and
the possible reasons are
The actually detected parameter value and running record parameter value
Some Function code parameter value can’t be modified while the NICE 1000 is running
3.2 Groups of function parameters
Press button and then or button, display will show the first level menu, which are
group of function. They are
F0 Basic Parameter
F1 Motor Parameter
F3 Running Control Parameter
F4 Floor Parameter
F5 Terminal Input Parameter
F6 Elevator Basic Parameter
F7 Terminal Output Parameter
F8 Build-up function Parameter
F9 Time Parameter
FA Keyboard setting Parameter
FB Door Function Parameter
FF Factory Parameter
FP User Parameter