5.5 NICE 1000 Parameter Adjustment :-
Connect the Operation LED Keypad as shown in below figure
5.5.1 Take down the motor parameter and encoder details; enter the following actual Parameter value in
NICE1000 using LED keypad.
Description
Parameter
Set actual value
Remarks
Motor Parameter Details
Rated Power (KW)
F1-01
Enter the correct Motor nameplate
value in to the corresponding Drive
Parameter
Rated Voltage (V)
F1-02
Rated Current (I)
F1-03
Rated Frequency (F)
F1-04
Rated Speed (RPM)
F1-05
Encoder Parameter Details
Encoder Type Selection
F1-00
0Syn 2Asyn
Enter the correct Encoder details
Pulse Per Revolution
(PPR)
F1-12
Elevator Running Speed Parameter Details
Rated speed of Elevator
F0-04
(Enter the Elevator
Rated speed in m/s)
Enter the Rated speed of the elevator
Max speed of Elevator
F0-03
(Enter the required
Max. speed in m/s)
Enter the Max speed of the Elevator
(Limited by Rated speed setting F0-04)
Slow speed
F3-11
Used for Inspection speed

Related product manuals