Version : 1.4
Date of issue : 03-07-14
5.5 NICE 1000 Parameter Adjustment :-
Connect the Operation LED Keypad as shown in below figure
5.5.1 Take down the motor parameter and encoder details; enter the following actual Parameter value in
NICE1000 using LED keypad.
Enter the correct Motor nameplate
value in to the corresponding Drive
Parameter
Encoder Parameter Details
Enter the correct Encoder details
Pulse Per Revolution
(PPR)
Elevator Running Speed Parameter Details
(Enter the Elevator
Rated speed in m/s)
Enter the Rated speed of the elevator
(Enter the required
Max. speed in m/s)
Enter the Max speed of the Elevator
(Limited by Rated speed setting F0-04)
Used for Inspection speed