7. Floor display Setting:-
NICE 1000 Lift Integrated Controller can provide three different output functions for third party
floor display.
They are
7 Segment output selection FE-12=0
Binary Code output selection FE-12=3
BCD output selection FE-12=1(Default)
For 7 segment function, set the following parameters
FE-12=0
F7-10=10
F7-11=11
F7-12=12
F7-13=13
F7-14=14
F7-15=15
F7-16=16
To modify the 7 segment floor display digit, use the following parameters
FE-01 to FE-10 for landing level 1 to 10
Parameter
Setting Value
7segment display output
FE-xx
1900
To display ‘0’
FE-xx
1901
To display ‘1’
FE-xx
1902
To display ‘2’
FE-xx
1903
To display ‘3’
FE-xx
1904
To display ‘4’
FE-xx
1905
To display ‘5’
FE-xx
1906
To display ‘6’
FE-xx
1907
To display ‘7’
FE-xx
1908
To display ‘8’
FE-xx
1909
To display ‘9’
FE-xx
1911
To display ‘b’
FE-xx
1912
To display ‘G’
FE-xx
1913
To display ‘H’
FE-xx
1914
To display ‘L’
FE-xx
1915
To display ‘n’
FE-xx
1916
To display ‘P’
Example setting for b+G+4 landing lift (6 Floors)
Parameter
New Setting
Display Type
FE-01(basement Floor)
1911
To display ‘b’ for basement Floor
FE-02 (Ground Floor)
1912
To display ‘G’ for Ground Floor
FE-03 (First Floor)
1901
To display ‘1’ for First Floor
FE-04 (Second Floor)
1902
To display ‘2’ for Second Floor
FE-05 (Third Floor)
1903
To display ‘3’ for Third Floor
FE-06 (Fourth Floor)
1904
To display ‘4’ for Fourth Floor