5.1.5 Verify that the following voltage levels are OK and within the limit
240VAC Level
± 24VDC Level
110VAC Level
±110VDC Level (If present)
5.1.6 After confirming the correct voltage level, switch OFF the Control Panel Circuit Breakers
5.1.7 Connect the Control terminal wiring on MCTC-MCB-G of NICE 1000
Connected the Safety circuit wiring to the field as per the Electrical drawing. Safety circuit terminal
starts from 101 and ends at 132 terminal
Connected the wiring for Up/Down terminal floor Limit and slowdown switches
The distance for terminal floor slowdown should be 1300mm~L/2 from the floor level and the distance for
terminal floor direction limit switches should be 30 to40 mm above the floor level in top terminal/ below the
floor level in bottom terminal
LTerminal floor height
For terminal slowdown, it can be calculated as follow
Slowdown distance (S) > (F0-04 * F0-04) / (2 * F3-08)
(Default: S=1500mm for 1mps)