Preparation Before Installation
‑21‑
EMC filter
Install the filter near the input terminals of the drive. The cable between the filter and
the drive must be shorter than 30 cm. Connect the grounding terminal of the filter
together with the grounding terminal of the drive. Ensure the filter and the drive are
installed onto the same conductive mounting surface that is connected to the main
grounding of the control cabinet.
3.5 Cable Preparation
There are many cables connecting to the drive, including the power supply cable,
power cable, encoder cable, control cable and communication cable. For detailed
cable specifications, see the hardware guide.
If you have special requirements on the cables, contact Inovance.