Electrical Installation
34
6 Electrical Installation
6.1 Safety Cautions
Observe the following requirements during wiring of the power supply and main
circuit:
When the main circuit terminal is a connector, remove the connector from the
servo drive before wiring.
Insert one cable into one cable terminal of the connector. Do not insert
multiple cables into one cable terminal.
When inserting cables, take enough care to prevent the cable conductor burrs
from being short circuited to the neighboring cable.
Insulate the connecting part of the power supply terminals to prevent electric
shock.
Do not connect a 220 V servo drive to a 380 V power supply directly.
Install safety devices such as a circuit breaker to prevent short circuit in
external circuits. Failure to comply may result in a fire.
Cut off the main circuit power supply and switch off the S‑ON signal after an
alarm signal is detected.
Do not put heavy objects onto cables or pull cables with excessive force. Failure to
comply may result in cable damage, leading to an electric shock.
Use a power supply filter to reduce the electromagnetic interference on electronic
devices surrounding the servo drive.
6.2 Wiring of the Power Supply
Single‑phase 220 V models: SV660FS1R6I, SV660FS2R8I, SV660FS5R5I, SV660FS7R6I
and SV660FS012I

Other manuals for Inovance SV660F Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Inovance SV660F Series and is the answer not in the manual?

Inovance SV660F Series Specifications

General IconGeneral
BrandInovance
ModelSV660F Series
CategoryServo Drives
LanguageEnglish

Related product manuals