Terminals
‑50‑
3.2.3 Encoder Frequency-Division Output Signals
The encoder phase Z frequency‑division output circuit supports open‑collector signal
output. Typically, this circuit provides feedback signals to the host controller in a
position control system. Use an optocoupler circuit, relay circuit, or bus receiver
circuit on the host controller side to receive feedback signals.
To reduce noise interference, use shielded twisted pairs to connect the 5V GND of the host
controller to the GND of the servo drive.
The maximum permissible voltage and current capacity of the optocoupler output
circuit inside the servo drive are as follows:
● Maximum voltage: 30 VDC
● Maximum current: DC 50 mA
3.2.4 Wiring of the Brake
The brake is used to prevent the motor shaft from moving and lock the position of the
motor and the motion part when the drive is in the non‑operational status.