Processor Subsystem
System Event Log Troubleshooting Guide for EPSD
Platforms Based on Intel
®
Xeon
®
Processor E5 4600/2600/2400/1600/1400 Product Families
62 Intel order number G90620-002 Revision 1.1
ED2
Description
Next Steps
01h
CATERR
This error is typically caused by other platform components.
1. Check for other errors near the time of the CATERR event.
2. Verify all peripherals are plugged in and operating correctly, particularly Hard Drives, Optical Drives,
and I/O.
3. Update system firmware and drivers.
2h
CPU Core
Error
1. Cross test the processors.
2. Replace the processors depending on the results of the test.
3h
MSID
Mismatch
Verify the processor is supported by your baseboard. Check your boards Technical Product Specification
(TPS).
6.3 CPU Missing Sensor
The CPU Missing sensor is a discrete sensor reporting the processor is not installed. The most common instance of this event is due
to a processor populated in the incorrect socket.
Table 51: CPU Missing Sensor Typical Characteristics
Byte
Field
Description
11
Sensor Type
07h = Processor
12
Sensor Number
82h
13
Event Direction and
Event Type
[7] Event direction
0b = Assertion Event
1b = Deassertion Event
[6:0] Event Type = 6Fh (Sensor Specific)
14
Event Data 1
[7:6] 00b = Unspecified Event Data 2
[5:4] 00b = Unspecified Event Data 3
[3:0] Event Trigger Offset = 1h (State Asserted)
15
Event Data 2
Not used
16
Event Data 3
Not used

Table of Contents

Other manuals for Intel S2600IP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intel S2600IP and is the answer not in the manual?

Intel S2600IP Specifications

General IconGeneral
BrandIntel
ModelS2600IP
CategoryMotherboard
LanguageEnglish

Related product manuals