Intel® Server RAID Controller U3-1 User’s Manual Rev 1.0 Glossary-3
Glossary
Online RAID Reconfiguration
Ability to switch the RAID level configuration without having to take the system offline.
Operating System Service Module (OSM)
The I
2
O OSM that handles the communication between the host CPU operating system and the I
2
O
Messaging Layer. The OSM is unique for each operating system.
Parity
A technique used to protect a system from data loss due to faults. When parity is implemented
(RAID3 and RAID 5), data written is logically XOR'd together to calculate parity which is stored
on the drives along with the data. In a system with three drives, the data is written to two drives and
the calculated parity is stored on a third drive. If one drive fails, data on the failed drive is
reconstructed from other data and parity.
RAID
Redundant Array of Independent Disks (RAID) refers to a method of organizing data on one or
more physical disks to provide increased I/O performance and data protection. The different
methods for organizing the data are referred to as RAID Levels. The RAID levels offered by
SRCU31are0,1,5and10.
RAID 0+1
A combination of RAID 1 and RAID 0. Provides high performance and high availability. Also
known as RAID 10.
RAID Level 0
Striping of data across multiple drives in an array. Very fast performance, however there is no data
protection.
RAID Level 1
Also known as mirroring. Mirroring refers to the 100% duplication of data from one disk to
another. Due to the 100% duplication, this is a costly solution.
RAID Level 10
A combination of RAID 1 and RAID 0. Provides high performance and high availability. Also
known as RAID 0+1.
RAID Level 5
Striping with parity. Data and parity information is spread among each drive in the drive group.
Parity requires 33% of the entire drive capacity in a 3 disk group and 20% of the entire drive
capacity in a 5 disk group. This provides a balance between performance and cost.
SAF-TE Support (SCSI Accessed Fault-Tolerant Enclosures)
A standard that allows third party disks and controllers to be automatically integrated with
peripheral enclosures that support status signals, hot swapping of drives and monitoring of fans,
power supplies and monitoring of the enclosure temperature of the disk drives.
Download from Www.Somanuals.com. All Manuals Search And Download.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intel U3-1 and is the answer not in the manual?

Intel U3-1 Specifications

General IconGeneral
BrandIntel
ModelU3-1
CategoryController
LanguageEnglish

Related product manuals