14 Intermec EasyLAN Wireless Interface Kit—Installation Instructions
Chapter 3—Setup in Fingerprint
Changing Passwords
To change the password for a user in Fingerprint, the “passwd”-command
is used.
Syntax:
RUN"passwd [<user>]"
passwd changes the users password. First, the user is prompted for the
current password (if it exists). If the current password is correctly typed,
a new password is requested. The new password must be entered twice to
avoid typing errors. The new password s total length must be
less than 128 characters. Numbers, upper-case letters and metacharacters
are encouraged. Valid user names are admin and user.
You can also use this command:
RUN"passwd <user> '<oldpasswd>' '<newpasswd>' '<newpasswd>'
Examples:
To change password for the current user (user, without password):
RUN"passwd"
Changing local password for user.
New password:[enter new password]
Retype new password:[enter new password]
To change password for ’admin’:
RUN"passwd admin"
Changing local password for admin.
Old password:[enter current password]
New password:[enter new password]
Retype new password:[enter new password]
Note: You do not have to change to the user whose password is
changed.
Active
While setting up the printer’s network settings, it is preferable that
the changes do not take effect until all the changes have been made.
All settings are saved to non-volatile memory immediately after the
command has been given, but they are not committed to the NIC/driver
until these “current” settings have been “activated.”