EasyLAN Wireless Interface Kit Installation Instructions 59
Chapter 5 — Setup in IPL
Setting Network Parameters in Manual Mode
Note: MANUAL mode is only supported by IPL 2.40 or later.
You can use MANUAL mode to assign a static IP address to the printer.
To assign network values manually, connect the printer to the serial port
on the host PC and open a communications program such as HyperTer-
minal. Send this command:
<SI>nn[,m1[,m2]]
where:
n is the IP address, in the format n.n.n.n, where n is a number in the
range 0-255
,m1 is the subnet mask address written in the same format
,m2 is the router address written in the same format
Sending this command places the printer in MANUAL mode automati-
cally if you specify at least two of the three parameters. If you specify
only one parameter, such as the IP address, you need to place the printer
in MANUAL mode via the printer's keyboard before you send the com-
mand. Otherwise, the command will have no eff ect.
You can confi rm the IP address by sending the upload confi guration
parameters command.
Examples:
<STX><SI>n192.168.235.86,255.255.254.0,192.168.234.
1<ETX>
Sets the IP address to 192.168.235.86, the subnet mask to
255.255.254.0, and the router to 192.168.234.1.
<STX><SI>n192.168.235.86<ETX>
Sets the IP address to 192.168.235.86 and uses the default subnet mask
and router settings. You need to place the printer in MANUAL mode via
the printer's keyboard before you send this command.

Other manuals for Intermec PM4I

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intermec PM4I and is the answer not in the manual?

Intermec PM4I Specifications

General IconGeneral
Print TechnologyDirect thermal / Thermal transfer
Resolution203 dpi
Max Print Width4.09 inches
ConnectivityUSB, Serial, Parallel
Optional ConnectivityEthernet, Wireless
Memory16 MB SDRAM, 8 MB Flash
Operating Temperature+5°C to +40°C (+41°F to +104°F)
Storage Temperature-20°C to +60°C (-4°F to +140°F)

Related product manuals