EasyManua.ls Logo

Interquartz IQ335 - OPERATING REQUIREMENTS AND DISPLAY; LINE, POWER, AND MEMORY NEEDS; LIQUID CRYSTAL DISPLAY DETAILS; MESSAGE WAITING SUPPORT

Interquartz IQ335
41 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3
OPERATING REQUIREMENTS
Any 2-wire analog line; if the IQ335’s Caller ID feature is required, please ensure that your line
delivers the necessary Caller ID data
240V mains outlet for 9V mains power adaptor (supplied) for full support of all functions
If 3 x AA Alkaline batteries (not supplied) are fitted in the absence of mains adaptor or during mains
power failure, they can provide up to one month’s support of all functions
If no adaptor or battery power available - basic telephone operation (will automatically power up
approximately 1 second after lifting handset)
Memory backup - no batteries required. All memories (except the Redial memory) are non-volatile; their
contents will be retained without any power
LIQUID CRYSTAL DISPLAY
Liquid Crystal Display with a row of useful icon indicators, a number field and a name field (16
characters each)
MESSAGE WAITING
The following types are supported:
PABX compatible to 80VDC signal with red LED indicator - some systems require the fitting of optional
circuitry
Polarity reversal (e.g. Ericsson BP250) message waiting light built-in with red LED indicator
Bellcore (e.g. Telstra Spectrum, Cisco and Nortel DMS) with both on-screen and LED indicators
Type 2 Caller ID Call Waiting (CIDCW) during a call

Table of Contents

Related product manuals