8
Version 2.0 (11/2013) en
Translation of the original instructions
DriveControl DC-20/DC-54
Product information
Speed settings The speed of the RollerDrive can be set with the DriveControl in two ways:
• internally via four DIP switches with 15 levels (is handled with priority and
enables finer setting levels)
• externally via three digital inputs with eight levels (speed modifications are
also possible in running operation, whereby a form of ramp function can be
implemented with corresponding switching of a PLC)
This speed setting is converted to an analogue control voltage by the
DriveControl and output by the RollerDrive as a reference setting. This reference
setting is independent of the RollerDrive gears and their diameter.
Speed setting of the see "Operation", page 24.
The acceleration and braking behaviour of the RollerDrive is defined by its own
moment of inertia, the gears used, the conveying speed, the moment of inertia of
the connected roller drives, the selected torque transmission and the goods
transported.