Goodrive170-PV Series Solar Pump Inverter Function parameter list
-23-
parameter because reverse running is not
allowed in water pump application
scenarios.
2: Disable reverse running. It can be used in
some special scenarios where reverse
running is disallowed.
Motor
parameter
autotuning
0: No operation
1: Rotary autotuning
Comprehensive motor parameter autotuning.
It is recommended to use rotating autotuning
when high control accuracy is needed.
2: Static autotuning 1
Used in scenarios where the motor cannot
be disconnected from load.
3: Static autotuning 2
Empty-load current and mutual inductance
are not autotuned.
Function
parameter
restore
0: No operation
1: Restore default values
2: Clear fault records
Note:
After the selected operation is
performed, the function code is
automatically restored to 0.
Restoring the default values may delete
the user password. Exercise caution
before using this function.
P01 group Start and stop control
0: Decelerate to stop. When a stop
command takes effect, the inverter lowers
output frequency based on the DEC mode
and the defined DEC time; when the
frequency drops to 0Hz, the inverter stops.
1: Coast to stop. When a stop command