EasyManuals Logo

INVT GD170-045-4-PV User Manual

INVT GD170-045-4-PV
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #28 background imageLoading...
Page #28 background image
Goodrive170-PV Series Solar Pump Inverter Function parameter list
-24-
Function
code
Name
Description
Default
Modify
takes effect, the inverter stops output
immediately. And the load coasts to stop
according to mechanical inertia.
P01.18
Terminal-based
running
command
protection at
power-on
0: The terminal running command is invalid
at power-on
1: The terminal running command is valid
at power-on
1
P01.21
Power-off
restart
selection
0: Disable restart
1: Enable restart
1
P02 group Parameters of motor 1
Function
code
Name
Description
Default
Modify
P02.00
Motor type
0: Asynchronous motor (AM)
1: Synchronous motor (SM)
0
P02.01
Rated power of
AM
0.1
3000.0kW
Used to set AM
parameters.
To ensure the control
performance, set
P02.01P02.05 correctly
according to the
information on the
nameplate of the AM.
The inverter provides the
parameter autotuning
function. Whether
parameter autotuning
can be performed
properly depends on the
settings of the motor
nameplate parameters.
In addition, you need to
configure a motor
according to the
standard motor
configuration of the
Model
depended
P02.02
Rated
frequency of
AM
0.01Hz
P00.03
50.00Hz
P02.03
Rated speed of
AM
136000rpm
Model
depended
P02.04
Rated voltage
of AM
01200V
Model
depended
P02.05
Rated current of
AM
0.86000.0A
Model
depended

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the INVT GD170-045-4-PV and is the answer not in the manual?

INVT GD170-045-4-PV Specifications

General IconGeneral
BrandINVT
ModelGD170-045-4-PV
CategoryInverter
LanguageEnglish

Related product manuals