Goodrive170-PV Series Solar Pump Inverter Function parameter list
-46-
Function
code
Name
Description
Default
Modify
0: Model -SS2, 220V 1PH input and 1PH
output
1: Model -S2, 220V 1PH input and 3PH
output
2: Model -2, 220V 3PH input and 3PH
output
3: Model -4, 380V 3PH input and 3PH
output
Setting range: 03
P15.40
PQ curve
fitting
enabling
0: Disable
1: Enable
Enable P15.40, and use the point between
P15.41 and P15.50 for PQ curve fitting
calculation. In this way, the flow calculation
will be more accurate.
0
P15.41
Power
point 1 of
PQ curve
It indicates the power point corresponding
to the pump input power at the 1
st
point of
the PQ curve.
0.0
P15.42
Power
point 2 of
PQ curve
It indicates the power point corresponding
to the pump input power at the 2
nd
point of
the PQ curve.
0.0
P15.43
Power
point 3 of
PQ curve
It indicates the power point corresponding
to the pump input power at the 3
rd
point of
the PQ curve.
0.0
P15.44
Power
point 4 of
PQ curve
It indicates the power point corresponding
to the pump input power at the 4
th
point of
the PQ curve.
0.0
P15.45
Power
point 5 of
PQ curve
It indicates the power point corresponding
to the pump input power at the 5
th
point of
the PQ curve.
0.0
P15.46
Flow point
1 of PQ
curve
It indicates the flow point corresponding to
the pump flow at the 1
st
point of the PQ
curve.
0.0
P15.47
Flow point
2 of PQ
curve
It indicates the flow point corresponding to
the pump flow at the 2
nd
point of the PQ
curve.
0.0