Single Phase Hybrid Inverter Troubleshooting
66
Communic
ation of
anti-reflux
meter
Check whether the smart meter is connected
properly and supplies power normally.
Communication
error of meter
Check whether the smart meter is connected
properly and supplies power normally.
Check whether the CT cable is connected
properly.
1. If the fault occurs occasionally, it may
be caused by momentary abnormality of the
power grid. The inverter will resume normal
operation when the power grid gets back to
normal.
2. If the fault occurs frequently, check
whether the power grid is connected properly.
Check whether the PV input is normal and
whether the circuit is short.
Reduce the load at the EPS port.
The battery is fully charged.
The battery needs
to be charged.
Please charge the battery soon.
The battery can
only be charged.
Check the priority mode settings and charge
the battery.