EasyManua.ls Logo

INVT XG50KTR

INVT XG50KTR
39 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Three-phase Grid-tied Solar Inverter Product overview
11
LED light display status description:
Indicator
light
Instruction
State
Description
Run
Grid-connect
ed indicator
light
Green light on
connected to grid
Green light off
Not connected to grid
Green light flashes 0.5s
On, 0.5s Off)
The inverter is in maintenance
status
Alarm
Alarm
indicator
Yellow light on
The inverter is in fault state
Yellow light flashes slowly
1s On, 4S Off
The Inverter is in alarm state
Yellow light flashes (0.5s on,
0.5s off)
The inverter is under
maintenance
Fault
The PV
connection
indicator light
Red light on
The power-on indicator light
indicates that at least one of the
photovoltaic strings is connected
normally and the input voltage is
≥200V
Red light off
The inverter is disconnected from
all PV strings, or the DC input
voltage of all MPPT circuits is
less than 200V
2.7 Bottom of the chassis
XG40-70KTR is equipped with a DC switch, which connects or disconnects all PV inputs.
XG50KTR Bottom view