EasyManuals Logo

Ion Technologies IT- DS05-S User Manual

Ion Technologies IT- DS05-S
43 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #38 background imageLoading...
Page #38 background image
IONTECH
®
IT-DS EDI Modules
Troubleshooting Flow Chart - Low EDI Product Water Quality
Page 2 of3
Continued from previous
flowchart
Product flow
increased?
Yes
Check IP-Pro:
is desired quality
possible?
Yes
Increase
DCamperage
No
Reduceflow
No orreducefeed
conductivity equivalent
HaveDCvolts
increased?
Yes
Seeseparate
troubleshooting
chart forDC volts
Go tochart for
DCVolts
No
Is reject out psi
> product out psi?
Yes
Adjust product out to
2-5 psi > reject out
No
Goto Next Flowchart
38 IT-DS MAN Rev 0

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ion Technologies IT- DS05-S and is the answer not in the manual?

Ion Technologies IT- DS05-S Specifications

General IconGeneral
BrandIon Technologies
ModelIT- DS05-S
CategoryControl Unit
LanguageEnglish