29
YEARLY: replace the glass cylinder and the external cap
Order the glass cylinder and external cap from IRINOX
CODE 3880410
0
Cut power from the conserver and
access Sanigen.
6
Make sure that the external cap covers the
internal cap. Maintain a distance of about
5mm from the red base
5
Re-screw the new glass cylinder with the
external cap clockwise, again acting
on the red plastic base.
1
Unhook the outside lug, holding the glass
cylinder still.
3
Dispose of the glass cylinder with the external
cap as dry waste, since it is made up of
recyclable materials.
4
Check to see if the new glass cylinder has
any cracks. If so, the glass cylinder
must be replaced.
2
Unscrew the glass cylinder anti-clockwise,
acting on the red plastic base.
7
Holding the glass cylinder still, re-insert the
external lug, making sure that it is contact
with the external cap.