16
BATCH MODE
Flow 000 %
Stop Stroke
Start Man.
BATCH MODE
Flow 000 %
Stop Stroke
Start Ext
BATCH MODE
Flow 000 %
Stop Stroke
Start Time
BATCH MODE
Stop Stroke
Start Man.
Flow 050 %
BATCH MODE
Start Man.
Flow 050 %
Stop 000050 St
Volume 01 , 379 l
BATCH MODE
Start Man.
Flow 050 %
Stop Stroke
ENT
ENT
Conguration
Ext.: start the pump via remote input
Stroke: select the number of cycles before stopping
Time: start the pump via a timer by entering a frequency
(00:00:01 - 23:59:59)
Batch dosing mode settings
4.1.4.1 Select start-up mode
Manual: start the pump by pressing
ENT
Change by pressing and conrm by pressing
ENT
Change by pressing and conrm by pressing
ENT
4.1.4.2 Select stroke frequency in % (ow)
4.1.4.3 Select stop mode