Output Commands
Copyright© Itech Electronics Co., Ltd. 21
[SOURce:]CHANnel:OUTPut[:STATe]
This command is used to control the output state (ON/OFF) of the current
channel.
Command syntax
[SOURce:]CHANnel:OUTPut[:STATe] <bool>
Arguments
0|1|ON|OFF
*RST Value
OFF
Query syntax
[SOURce:]CHANnel:OUTPut[:STATe]?
Returns
0|1
[SOURce:]OUTPut:PROTection:CLEar
This command is used to clear the protection state.such as OVP,OTP.
Command syntax
[SOURce:]OUTPut:PROTection:CLEar
Arguments
None