Function and Features
Copyright ©ITECH Electronics Co., Ltd. 21
Rst will not initialize the system setting and configuration setting. If Sav0 is
selected, the parameters will be all setting values at the time of last power-off,
including output and input setting values of the power supply.
Trigger Mode ( >Trigger)
Trigger is used for trigger the output of voltage, current and power, and there’re
three kinds of trigger options: Manual, Bus, and Ext. The default settings is
Manual
Manual: the trigger signal will be given by composite keys
[Shift]+[Enter]( Trigger )
Bus: bus trigger mode.
Ext: external signal trigger.
Save Group Operation ( Memory)
Power source can save 100sets parameters in nonvolatile memory by the save
group setting.This operation provides the customer with a convenient and quick
save/recall using condition.
GRP0: save( recall) power source parameters in 0-9 sets.Press
[Shift]+
[Recall]
( Save)+0-9 numeric keys( [Recall] +0-9 numeric keys to recall the
parameters)
GRP1: save( recall) parameters in 10
th
-19
th
sets.Press [Shift]+
[Recall]
( Save)+numbers1-9 to save the parameters( [Recall] +numbers1-9 to
recall parameters).Under this condition,number 1 represents to save or
recall the 10
th
parameters.Number 2 represents to save or recall the
eleventh parameter.GRP2-GRP9 can be understood in the same manner.
Key Sound Set( >Buzzer)
This item can set the buzzer state.On option indicates that when you push
buttons,the buzzer will sound.Off option indicates that the buzzer function is
disabled.Factory default is On option.
Communication Set( >Communication )
Under this item,you can set the concrete communication mode.This unit has
provided multiple communication interfaces: RS232/USB/GPIB/LAN/CAN.Of
which,the GPIB are addressable from 0-31.The baudrate options of RS232 are
4800,9600,19200,38400,57600,115.2K.Data bit is 8bits.Parity bit has three
options: NONE,ODD,EVEN.Please ensure the configuration consistency
between our instrunment and PC,so that you could have a successful
communication.
Return to Meter state( > Return Meter)
This option allows users to enable an internal fixed timer delay ( 5 seconds) for
the power supply to automatically switch from setting display to measured
display. When enabled, if the power supply output state is ON ( enabled) and if
the display shows setting voltage and current, it will automatically switch to
measured voltage and current display after 5 seconds.
Power On Output State (> P-OUT)
This item can set the power on output state. If you select Last item, that
indicates the power on output state is the same with output state before this
item is set. If you select Off item, unit will automatically in off mode when you

Table of Contents

Other manuals for ITech IT6522D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT6522D and is the answer not in the manual?

ITech IT6522D Specifications

General IconGeneral
BrandITech
ModelIT6522D
CategoryPower Supply
LanguageEnglish

Related product manuals