Remote Control 
  Copyright ©ITECH Electronics Co., Ltd.  39 
interface,please check the following items:   
  Please check the parameters setting 
PC and power supply must have the same configuration in the following 
items:    baudrate,  parity bit,data bit and flow control.Please note that 
power supply has been configured with a start bit and stop bit( the two 
values are fixed). 
  Check the cable 
Ensure you have used the correct communication cable.Please pay 
attention that some cable may not have a correct internal wiring even it is 
with a appropriate DB9 interface. 
The RS232 communication cable should have been connected to a correct 
serial port of the PC. 
Communication Setup 
Please ensure the PC and power supply have the same configuration in the 
following items. 
baudrate:    9600( 4800, 9600, 19200, 38400, 57600, 115200).You could enter 
the system menu to set the baudrate. 
Data bit:    8 
Stop bit:    1 
Parity bit:    ( none, even, odd)   
EVEN      8 data bits have even parity
 
ODD    8 data bits have odd parity 
NONE    8 data bits have no parity
 
Native machine address:   ( 0 ~31, factory default is 0)   
Start Bit  8 Data Bits  Stop Bit 
4.2 USB Interface 
Use a cable with two USB ports to connect power supply and PC.You can 
program through USB interface to achieve all functions of power supply. 
The functions of USB488 interface are as follows:   
  Interface is 488.2 USB488 interface 
  Receive the following request:    REN_CONTROL,  GO_TO_LOCAL,  and 
LOCAL_LOCKOUT 
  When the interface receives MsgID =  TRIGGER USBTMC command,it 
will transmit the TRIGGER command to the function layer 
The functions of power supply’s USB488 are as follows:   
  receive all SCPI commands 
  device is SR1 enabled 
  device is RL1 enabled 
  device is DT1 enabled 
4.3 GPIB Interface 
Use a IEEE488 bus to connect GPIB interfaces of power supply and PC.Please 
ensure that the screws have been screwed down in order to  have a full