EasyManuals Logo

ITech IT7622 User Manual

ITech IT7622
95 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #81 background imageLoading...
Page #81 background image
Technical Specifications
Copyright ©ITECH Electronic Co., Ltd. 79
Accuracy
±0.3%+(0.3%+0.2%×Kfreq)×FS
*2
Temp.
coefficient
±(0.04% per degree from 25°C)
Power
Resolution
10mW
Accuracy
±0.4%+(0.4%+0.2%×Kfreq)×FS
*2
Temp.
coefficient
±(0.04% per degree from 25°C)
Phase Angle
Range 0-360°
Resolution
Accuracy
±1°(45-65Hz)
*5
Frequency
Range
10-5KHz
Resolution
0.1Hz
Accuracy ±0.1%+0.1Hz(10Hz-999.9Hz)/±0.1%+1Hz(1KHz-5KHz)
*4
Other
Protection
OVP, OPP, OCP, OTP
Interface
GPIB, USB, LAN, RS232, CAN
Dimension(WxHxD)
3u
*1
: Precondition for voltage accuracy: Slow loop speed: 10-100Hz; Fast loop
speed: 10-5KHz.
*2
: FS= Full Scale: Vrms=300Vac, Irms=12A; Ipk=36A; P=1500VA.
*3
: The minimum voltage of THD test is 10Vac (Auto mode) and 20Vac (High
mode).
The maximum distortion test is carried out by outputting the maximum current
to linear load under 125Vac (Auto mode) and 250Vac (300V mode).
*4
: The test frequency accuracy should ensure that the minimum voltage is
30Vac.
*5
: Testing premise is in Fast mode
*6
: The minimum voltage setting must not be less than 50Vdc.
*7
: FS=full: Vdc=424Vdc; Idc=6A; P=750W.
Parameter IT7626 V1.6
AC Input
Voltage
220Vac±10%
Phase
single phase
Frequency
10-5kHz
ООО "Техэнком" Контрольно-измерительные приборы и оборудование www.tehencom.com

Table of Contents

Other manuals for ITech IT7622

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT7622 and is the answer not in the manual?

ITech IT7622 Specifications

General IconGeneral
BrandITech
ModelIT7622
CategoryPower Supply
LanguageEnglish

Related product manuals