Input Settings
Copyright © ITECH Electronic Co., Ltd. 36
[SOURce:]RESistance[:LEVel][:IMMediate][:AMPLitude]
<NRf+>
This command is used to set the resistance setting in CR mode.
Command Syntax
[SOURce:]RESistance[:LEVel][:IMMediate][:AMPLitude] <NRf+>
Parameters
MIN~MAX|MINimum|MAXimum
Unit
ohm
*RST Value
MAXimum
Examples
RES 5
Query Syntax
[SOURce:]RESistance[:LEVel][:IMMediate][:AMPLitude]?
Returned Parameters
<NR2>
[SOURce:]RESistance[:LEVel][:IMMediate][:AMPLitude
]?
This command is used to query the resistance setting in CR mode.
Command Syntax
[SOURce:]RESistance[:LEVel][:IMMediate][:AMPLitude]?
Parameters
None
Unit
ohm
*RST Value
MAXimum
[SOURce:]DYNamic:HIGH[:LEVel] <NRf+>
This command is used to set the high-level load current in dynamic mode.