Loading...
OCP Testing Commands
Copyright © ITECH Electronic Co., Ltd. 48
Chapter7 OCP Testing Commands
OCP[:STATe] <bool>
This command is used to set the OCP test status.
Command Syntax
OCP[:STATe] <bool>
Parameters
0|1|OFF|ON
Examples
OCP ON
Query Syntax
OCP[:STATe]?
Returned Parameters
0|1
OCP[:STATe]?
This command is used to query the OCP test status. At the end of OCP test, it
returns 0.
Command Syntax
OCP[:STATe]?
Parameters
0|1|OFF|ON
OCP:ISTart <NRf+>
This command is used to set the start current of the OCP test.
Command Syntax
OCP:ISTart <NRf+>
Parameters
MIN~MAX
Unit
A