Load Commands
Copyright © Itech Electronic Co., Ltd. 23
Parameter:
MINimum|MAXimum|DEFault or NRf
Reset value:
MINimum
Unit:
A
Query Syntax:
[SOURce:]CURRent[:LEVel][:IMMediate][:AMPLitude]? [MINimum|MAXimum]
Returned value:
NR3
[SOURce:]CURRent:LIMit[:LEVel][:CV]
This command is used to set the maximum current value in CV mode.
Command syntax
[SOURce:]CURRent:LIMit[:LEVel][:CV]
Parameter:
MINimum|MAXimum|DEFault or NRf
Unit
A
Reset value:
MAXimum
Query Syntax:
[SOURce:]CURRent:LIMit[:LEVel][:CV]? [MINimum|MAXimum]
Returned value
<NR3>
CURRent:PROTection
This command is used to set software overcurrent protection level ofelectronic