Calibration Commands
Copyright © Itech Electronic Co., Ltd. 57
Parameter:
P1|P2|P3|P4
CALibrate:RESistance
This command is used to calibrate the measurement resistance point.
Command syntax:
CALibrate:RESistance[:LEVel] <NRf> ,<NRf>
Parameter:
Voltage< external reading >, Current< external reading >
Unit:
V,A
CALibrate:RESistance:BIAS:POINt
This command is used to calibrate the bias point of resistance.
Command syntax:
CALibrate:RESistance:BIAS:POINt <point>
Parameter:
P1|P2|P3|P4
Unit:
None
CALibrate:RESistance:BIAS
This command is used to calibrate the bias level of resistance.
Command syntax:
CALibrate:RESistance:BIAS[:LEVel] <NRf>,<NRf>
Parameter:
Voltage< external reading >, Current< external reading >
Unit:
V,A