Steam is coming out of the mixer tap.
Cause Solution
a) The thermostat or safety thermal cut-out
is faulty.
Disconnect the appliance from the mains
power.
Contact your installer or service
organisation.
The heater is causing a short circuit
Cause Solution
a) There is a short circuit in the electrical
wiring or the heater element.
Disconnect the appliance from the mains
power.
Contact your installer or service
organisation.
No expansion water is coming out of the safety group
Cause Solution
a) Defective safety group. Disconnect the appliance from the mains
power.
Replace the safety group.
b) No water in the heater. Fill the heater with water.
c) The heater is OFF (standby) [dependent on
model].
Switch the heater ON.
d) The heater has encountered an error. The heater must be reset.
e) Heating element is broken. Disconnect the appliance from the mains
power.
Contact your installer or service
organisation.