7. The most frequent
complaints
The following is an overview of the most
common complaints known to Itho Daalderop.
For each of these complaints there are a
number of possible causes with a solution given
in each case, however, further research may be
needed to resolve a complaint.
Tip
If you cannot resolve the complaint yourself,
please contact your installer or service
organisation.
Water leak.
Cause Solution
a) Connection is leaking. Check the coupling(s) and tighten if
necessary.
Replace the coupling(s) if necessary.
b) Heater is leaking. Shut off the water supply.
Disconnect the appliance from the mains
power.
Contact your installer or service
organisation.
c) Tap is leaking. Shut off the water supply.
Contact your installer or service
organisation.
Mixer tap does not dispense water.
Cause Solution
a) The mains water tap is shut off. Open the mains water tap.
b) The valve of the safety group is shut off. Open the valve of the safety group.
Mixer tap only dispenses cold water.
Cause Solution
a) There is no power to the heater. Check the mains power and reset the
tripped circuit.
b) The heater is in STANDBY mode. Switch the heater ON.
c) The heater has encountered an error. The heater must be reset.
Reduced water flow or excessive splashing.
Cause Solution
a) Scaling and/or dirt on perlator. Descale and/or rinse the perlator.
b) Water pressure is too low (˂ 2 bar). Contact your water supplier.
c) The valve of the safety group is not fully
open.
Open the valve of the safety group.
d) The safety group is fouled. Replace the safety group.