EasyManua.ls Logo

Itho Daalderop Smartboiler - Page 42

Default Icon
48 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
E08 | 8
Software error
Cause Solution
a) The software does not work properly. 1. The appliance automatically resets itself a
maximum of three times.
2. Replace the control board.
E09 | 9
Hardware error
Cause Solution
a) The sensor data is not updated by the ADC. 1. Reset the error.
2. Replace the control board.
E10 | 10
Safety thermal cut-out
Cause Solution
a) Overheating of hot water temperature sensor. 1. Reset the error.
2. Replace the sensor.
3. Replace the control board.
E11 | 11
Temperature sensor error
Cause Solution
a) Too great a variance in the hot water
temperature sensor.
1. Reset the error.
2. Replace the sensor.
3. Replace the control board.
E12 | 12
Hardware error
Cause Solution
a) Phase relay does not work properly. 1. Reset the error.
2. Replace the control board.
E13 | 13
Hardware error
Cause Solution
a) Neutral relay does not work properly. 1. Reset the error.
2. Replace the control board.
E14 | 14
Software error
Cause Solution
a) Incorrect value in the EEPROM. 1. Reset the error.
2. Replace the control board.
42